Anti-lag Configuration

Configuration for the Anti-lag system.

Basic Settings

Parameter Type Description
enabled Boolean Master switch for Anti-lag system

Timing Settings

Activation Time

Parameter Type Description Valid Values
max_activation_time.enabled Boolean Enables maximum activation time limit  
max_activation_time.time Integer Maximum activation duration 0-30000ms

Cooldown

Parameter Type Description Valid Values
activation_cooldown.enabled Boolean Enables activation cooldown  
activation_cooldown.time Integer Cooldown duration 0-30000ms

Engine Control

RPM Hold

Parameter Type Description Valid Values
rpm_hold.enabled Boolean Enables RPM hold  
rpm_hold.mode String Hold implementation method “dwell” or “fuel”
rpm_hold.amount Integer Cylinders to cut (fuel mode) 1 to total cylinders

Ignition Retard

Parameter Type Description Valid Values
retard.enabled Boolean Enables ignition retard  
retard.mode String Retard control mode “fixed” or “dynamic”
retard.amount Integer Fixed retard amount -50-0°
retard.min_ignition Integer Minimum retard (dynamic) -50-50°
retard.max_ignition Integer Maximum retard (dynamic) -50-50°
retard.ignition_gain Number Retard adjustment per bar -200-200°

Auto Launch

Parameter Type Description Valid Values
auto_launch.enabled Boolean Enables auto launch  
auto_launch.boost_target_offset Integer Boost target adjustment -3000-3000 hPa
auto_launch.min_activation_time Integer Minimum activation time 100-5000ms
auto_launch.stalk Integer Required stalk position 0-8

Activation Settings

Trigger Conditions

Parameter Type Description Valid Values
trigger.enabled_maps Integer[] Enabled map numbers 0-8
trigger.min_rpm Integer Minimum RPM required 0-8000 RPM
trigger.min_pedal Integer Minimum pedal position 0-100%
trigger.stalk Integer[] Valid stalk positions 0-8

Additional Controls

Parameter Type Description Valid Values
mil.enabled Boolean Enables MIL indication  
enrichment.enabled Boolean Enables fuel enrichment  
enrichment.amount Integer Enrichment percentage 1-100%