HPFP Deviation
The HPFP deviation Guardian monitor is used to monitor the deviation between the requested and actual high pressure fuel pump pressure. This is useful for monitoring the health of the HPFP and detecting any issues with the fuel system.
Configuration
Enabled
Whether or not the HPFP deviation Guardian monitor is enabled.
Trigger
The trigger value for the HPFP deviation Guardian monitor. This is the threshold at which the monitor will trigger.
The value represents the maximum allowed deviation between requested and actual pressure in bar
.
Limp
Whether or not the vehicle will enter limp mode when the HPFP deviation Guardian monitor triggers.
Min Relative Load
The minimum relative load that the engine must be under for the HPFP deviation Guardian monitor to trigger.
Min Time
The minimum time in milliseconds that the HPFP deviation must be above the trigger value to actually trigger the Guardian monitor. This is to prevent false triggering due to momentary spikes in pressure deviation. If set to 0 it will trigger immediately.